Sign in →

Test Code 5904467 SOLUBLE TRANSFERRIN RECEPTOR (STFR)

Test ID

1239002342

Specimen Requirements

Collection Requirements Serum or Plasma, Refrigerated
Shipping / Handling Instructions Collect
Serum separator tube or plasma separator tube. Also acceptable: green (sodium or lithium heparin), lavender (EDTA), or pink (K2EDTA).
Specimen Preparation
Transfer 1 mL serum or plasma to an ARUP Standard Transport Tube. (Min: 0.3 mL)
Storage/Transport Temperature
Refrigerated.
Unacceptable Conditions
Contaminated, severely hemolyzed, icteric, or lipemic specimens.
Remarks
Stability
After separation from cells: Ambient: 72 hours; Refrigerated: 1 week; Frozen: 1 month (avoid repeated freeze/thaw cycles)

Container Type

Laboratory Container Default Temperature Minimum Volume
ARUP SST Yes Refrigerated 0.3

Performing Section

ARUP

Components

Component Name Component ID LOINC Code
SEE SCANNED RESULT 1813000
SOLUBLE TRANSFERRIN RECEPTOR (STFR) 1239003438 30248-9 (Transferrin receptor.soluble:MCnc:Pt:Ser/Plas:Qn:)