Test Code FDILT Diltiazem (Cardizem, Dilacor)
Reporting Name
Diltiazem (Cardizem,Dilacor)Performing Laboratory
Medtox Laboratories, Inc.Specimen Type
VariesSpecimen Required
Submit only 1 of the following specimens:
Plasma
Draw blood in a green-top (sodium heparin) tube(s), plasma gel tube is not acceptable. Spin down and send 3 mL sodium heparin plasma refrigerated in a plastic vial.
Serum
Draw blood in a plain, red-top tube(s), serum gel tube is not acceptable. Spin down and send 3 mL of serum refrigerated in a plastic vial.
Specimen Minimum Volume
0.6 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Varies | Refrigerated (preferred) | 14 days | |
Frozen | 180 days | ||
Ambient | 72 hours |
Reject Due To
Hemolysis | NA |
Lipemia | NA |
Icteric | NA |
Other | NA |
Reference Values
Reference Range: 50 - 200 ng/mL
Day(s) Performed
Monday through Sunday
CPT Code Information
80299
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
FDILT | Diltiazem (Cardizem,Dilacor) | 6898-1 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
Z1188 | Diltiazem | 6898-1 |
Report Available
3 to 7 daysMethod Name
High Performance Liquid Chromatography with Ultraviolet Detection (HPLC-UV)